Hub › Water › Water heater in an outage
Power's out. Is there still hot water?
Tap your heater type, tank and household. See if it still heats, how many hot showers are left, and what keeps it running.
1What kind of water heater?
Not sure? A cord to an outlet or a fan on top means it needs power. No cord and a metal pipe up a chimney means it doesn't.
2Tank size
3Who needs hot water each day?
4Backup battery to plug it into
Math (estimates): a shower uses flow × minutes, and about 78% of that is tank water at 120°F mixed down to 105°F with 50°F winter supply water. About 70% of a tank comes out hot before it runs lukewarm (plumber rule of thumb). Plus 2 gal of hot water per person per day for sinks. Gas tank with a plug: the blower runs only while the burner fires; we use ~200 W while firing (a common replacement blower is rated 1.8 A at 115 V) plus ~5 W standby, and a 40,000 BTU/h burner at 80%. Gas tankless: ~100 W while water flows plus ~5 W standby; outdoor freeze protection adds ~100 W for 12 cold hours a day. Battery: 85% of rated Wh reaches the outlet. Planning numbers, not tests of any heater.
Read before you plug anything in
- Hardwired heater? Don't improvise a cord. Only heaters that already plug into an outlet can go on a UPS or power station. Anything else needs an electrician.
- Electric tank: shut the breaker off if the tank might get drained. Power back on with an empty tank burns out the elements.
- Outdoor tankless in a freeze with no power: most makers say drain it. Check your manual before the storm.
- Any gas appliance: keep a battery CO alarm working. Headache, dizziness or nausea: get out and call 911.
Stretch the hot water
- Use the hot water early. A full tank cools slowly, but it never reheats while the power is out (unless it's a pilot-flame gas tank).
- Short showers, low-flow head. Every minute you cut is about 1.5–2 gal of hot water saved.
- Your tank is also stored drinking water if the taps stop. Shut the cold inlet valve first so it stays clean.
- Power vent: buy pure sine. A cheap modified-sine UPS may not light the burner. Test it before an outage.
Rheem and A.O. Smith list residential power-vent tanks at up to about 5 A at 120 V; that's the maximum, so we size the backup to your label amps × 120 V. Gas tankless units list their own amps on the rating plate. Electric tanks usually use 4,500 W elements on 240 V: a power station can't run one, and a generator needs a 240 V outlet plus an electrician-installed transfer switch or interlock. Watts while running are not published by most makers; measure yours with a plug-in watt meter. Planning information only.