Power's out. Gas furnace won't run.

Your gas is fine. The blower and controls need electricity. Tap 4 buttons: get hours of heat from a power station.

1Furnace blower

2How cold is it?

3Power station size

4Also running? (tap any)

5How long must it last?

—

Average draw—
Battery for your target—
Continuous output needed—
Surge rating to look for—

Math: usable Wh = capacity × 85% (inverter loss) ÷ average watts. Average = furnace watts × share of time it runs + extras. Estimates, not guarantees. Your nameplate or a plug-in meter beats our defaults.

Before you plug anything in

  • Most furnaces are hardwired. Have a licensed electrician add a furnace transfer switch or inlet. No back-feeding through an outlet.
  • Newer furnaces can need a neutral-bonding plug or a station with a bonded neutral to light. Check the manual.
  • Fuel generators go outside, 20 ft from doors and windows. Running gas heat? Test your CO alarms: CO alarm planner.
  • Turning the thermostat down a few degrees lowers how often it runs, so the battery lasts longer.

Wattage defaults: ~550 W (older PSC) and ~420 W (brushless) blower draw from a DOE Building America field study; 875 W for a larger fan from Honda's generator wattage chart; CPAP 56 W from ResMed's AirSense 11 typical use. Fridge, sump and Wi-Fi averages are rough estimates, labeled as such.